Home About us Products Quality Control Tech Info Contact us
HomePage » PRODUCTS » Battery powered ultrasonic flow meter » Battery powered ultrasonic flow meter <<     >>  
 
Description:  
                       Battery powered Ultrasonic water meter
                                               Advanced transit-time technology for flow accurate measurement
                                                                           Low cost, high performance---ABTDS-100W
Descriptions:

Applied with Euro standard of EN1413, Ultrasonic water meter is a super low consumption water meter with high-accuracy industry electronic parts equipped. It has many advantages such as: high accuracy, good reliability, no moving parts, no pressure drop, Low maintenance, etc. It is a excellent substitution of other water meters. With high quality parts and advanced technology, the ultrasonic flow meter/water meter have reached a very excellent performance.

Unlike mechanical water meters,the ultrasonic water meter has an outstanding long-term stablity. There is no moving parts in its sensor, so its performance doesn't degrade over time,its overall system accuracy doesn't also degrade over time.

Features:
(1)    Measuring accuracy:  ±1% or 2% of reading value
(2)    No pressure loss and no moving parts, designed for no maintenance for about 10 years
(3)    Measuring pipe founded by mould, no discharging
(4)    IP68 protection class, workable under 2 meter depth of water
(5)    Low start-up flow rate, the lowest flow speed measured is 0.03m/s
(6)    High temperature resistant and abrasion resistant transducer,  working temperature -40℃~155℃
(7)    RS485 port, support MODBUS,M-BUS,etc

(8)    Integrated type and none integrated type
(9)    Ultrasonic time-difference principle
(11)    Measuring period: 10S
(12)    Power supply: battery powered and DC8-36V. Battery can work for 5 years sequently.
(13)    Horizontal display and Down-looking display
(14)     Integrated inversion and separating version
(15)   GSM remote data reading
(16)   Seperating version support  clamp-on type and insertion type transducers.
(17)   An ideal choice for installing place without external power source 

Specifications:
Item Detailed parameter
Pipe Material Carbon Steel or stainless steel optional
Fluids measured Water, sewage and other homogeneous fluids
Accuracy ±1%  or ±2%  of reading value
Pipe Size Adaptable

DN15mm-DN1000mm (Inline type transducers)

DN80mm-DN800mm (Insertion type transducers)

DN15mm-DN800mm (Clamp-on type transducers)

Max.Pressure 4.0MPa (DN15-DN40mm)
1.6MPa(DN50-DN450mm)
1.0MPa(DN500-DN600mm)
0.6MPa(DN700-DN1000mm)
Other pressure request, please inform in advance while order
Working Environment Environmental temperature: -10~70℃.For special temp.,please contact us.
Flow material temperature -40~155℃
Output Signal (Selectable)

OCT output;

RS485 port support MODBUS, M-BUS;

USART(TTL level) output;,

GSM meter readings radio transmission;

Data Displayed Instantaneously flow rate, m3/h Cumulative flow rate, m3 , Flow rate, power of battery, Signal intension, Signal quality, Date, Time
Data Storage Storage of cumulative flow rate and cumulative effectively running time in EEPROM (Data can be saved for long term after power fail)
Power Supply Powered by battery capable of sustaining a continuous meter operation for over 5 years just need one lithium battery(3.6V/19AH)
Protection Class IP68, workable below water
Class of explosion resistance of explosion-proof transducer    ExdllBT4
Measuring Cycle 10 seconds per time(Default). 500mS-49S optional
Sampling times 64 groups(Default).32-128 groups optional
Other function

Automatically display common used result circularly
Cumulative unit 1、0.1、0.01、0.001、0.0001 m3 optional
Baud rate: 300、1200、2400、4800

Automatically record  the following information:

1) the NEG/POS/NET totalizer of the last  512days/128months/10years

2)the time and corresponding flow rate of the last 30 times of power ON/OFF events. Allow manual and automatic flow loss compensation.

Programming functions Unique patent designed circuit ensures water meter work well in execrable surrounding
***The new version battery powered unit can support clamp-on type sensors and insertion sensors.
 
                           
                         DN15-DN40mm                                                             DN50-DN1000mm
   
                             (PI type)                                                                         (Flow cell type)
                       
               DN80-DN800mm                                                  DN80-DN800mm
                (Insertion type)                                                    (clamp-on type)
 

Back>>