<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>heremeter.com</title>
	<atom:link href="http://www.heremeter.com/feed" rel="self" type="application/rss+xml" />
	<link>http://www.heremeter.com</link>
	<description></description>
	<lastBuildDate>Mon, 16 Jan 2012 06:30:16 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.3.1</generator>
<xhtml:meta xmlns:xhtml="http://www.w3.org/1999/xhtml" name="robots" content="noindex" />
		<item>
		<title>Responsibility to Implement Emissions Reduction</title>
		<link>http://www.heremeter.com/responsibility-emissions-reduction.html</link>
		<comments>http://www.heremeter.com/responsibility-emissions-reduction.html#comments</comments>
		<pubDate>Sun, 11 Dec 2011 14:03:36 +0000</pubDate>
		<dc:creator>heremeter</dc:creator>
				<category><![CDATA[News]]></category>

		<guid isPermaLink="false">http://www.heremeter.com/?p=687</guid>
		<description><![CDATA[The Department of environmental protection and local Govern.leaders to check responsibility to implement emissions reduction It was reported that the Ministry of environmental protection official, signed between the Government and State &#8211; owned enterprise leaders throughout the Department of environmental protection and energy &#8211; saving emission reduction objective responsibility, mandatory implementation of emission reduction objectives. [...]]]></description>
			<content:encoded><![CDATA[<p>The Department of environmental protection and local Govern.leaders to check responsibility to implement emissions reduction</p>
<p>It was reported that the Ministry of environmental protection official, signed between the Government and State &#8211; owned<br />
enterprise leaders throughout the Department of environmental protection and energy &#8211; saving emission reduction objective<br />
responsibility, mandatory implementation of emission reduction objectives.</p>
<p>Environmental Protection Department early this year to determine the emission reduction task is to include the chemical<br />
oxygen demand, ammonia, nitrogen, sulphur dioxide and nitrogen oxide emissions of four major pollutants down 2010.<br />
But pollutant emission total control of the Department of environmental protection Secretary Liu Bingjiang that, judging from the<br />
current test results hard to complete the established tasks.</p>
<p>Liu Bingjiang said: The first half of this year, two old pollutant emission total decrease of 1.74 and 1.63 respectively, completing<br />
the annual target is expected.Two new pollutants, ammonia emissions fell 0.73 nitrogen oxide reduction not reverse rise, and<br />
rose to 6.17, complete the target task extremely difficult.Pollution reduction there is also a responsibility to implement is not in<br />
place, security policy was not introduced, inadequate incentive and constraint mechanism, regulatory capacity is not strong<br />
reasons.</p>
<p>It is known that the next Department of environmental protection with the relevant departments on the chemical industry,<br />
especially nitrogen industry focused on governance. For those who can&#8217;t finish the construction of key projects and business<br />
groups, will be to limit the approval of sanctions.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.heremeter.com/responsibility-emissions-reduction.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Battery Powered Clamp-on Ultrasonic Water Meter</title>
		<link>http://www.heremeter.com/battery-clampon-sonic-water-meter.html</link>
		<comments>http://www.heremeter.com/battery-clampon-sonic-water-meter.html#comments</comments>
		<pubDate>Mon, 19 Sep 2011 11:21:14 +0000</pubDate>
		<dc:creator>heremeter</dc:creator>
				<category><![CDATA[Product]]></category>
		<category><![CDATA[clamp on flow meter]]></category>
		<category><![CDATA[ultrasonic water meter]]></category>

		<guid isPermaLink="false">http://www.heremeter.com/battery-powered-clamp-on-ultrasonic-water-meter.html</guid>
		<description><![CDATA[Ultrasonic water meter is developed from ultrasonic flow meter and powered by battery and only for water flow measurement.Because ultrasonic water meter carryies on many good features from ultrasonic flow meter,such as no moving parts,no pressure drop,completed communication protocol,etc, and ultrasonic flow converter and sensor are IP68 class,ultrasonic water meter will be an ideal choice [...]]]></description>
			<content:encoded><![CDATA[<p><a href="http://www.heremeter.com/wp-content/uploads/2011/09/clampontypeultrasonicflowtransmitter.jpg"><img style="display: inline; border: 0px;" title="" src="http://www.heremeter.com/wp-content/uploads/2011/09/clampontypeultrasonicflowtransmitter_thumb.jpg" alt="" width="216" height="240" border="0" /></a></p>
<p>Ultrasonic water meter is developed from <span class='wp_keywordlink'><a href="http://www.heremeter.com/" title="ultrasonic flow meter">ultrasonic flow meter</a></span> and powered by battery and only for water flow measurement.Because ultrasonic water meter carryies on many good features from ultrasonic flow meter,such as no moving parts,no pressure drop,completed communication protocol,etc, and ultrasonic flow converter and sensor are IP68 class,ultrasonic water meter will be an ideal choice for water meter as the cost is reduced.</p>
<p>Clamp-on ultrasonic water meter refers to the flow transducer is clamp-on type,which is clamped onto pipe surface.Clamp-on installing way doesn’t need to cut pipe,so there is no pressure drop,no risk of leakage,no maintainance,etc. But as it is battery powered,clamp-on ultrasonic water meter can’t get the same accurate level as that of main powered ultrasonic flow meter.Thus,battery powered clamp-on ultrasonic water meter is only for such request.Usually,we recommend main powered ultrasonic flow meter or battery powered ultrasonic water meter with insertion type sensor or spool piece inline type sensor.Though clamp-on ultrasonic water meter is not perfect yet, it is a very promising water flow meter once its accuracy is improved.We will try to our best to improve it.</p>
<p>If you have such request, please feel free to contact us: <a href="mailto:sales@heremeter.com">sales@heremeter.com</a></p>
<p>Our technicians will assist you for a proper solution.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.heremeter.com/battery-clampon-sonic-water-meter.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Low Cost Ultrasonic Flow/heat meters</title>
		<link>http://www.heremeter.com/product-id-38.html</link>
		<comments>http://www.heremeter.com/product-id-38.html#comments</comments>
		<pubDate>Fri, 09 Sep 2011 08:42:15 +0000</pubDate>
		<dc:creator>heremeter</dc:creator>
				<category><![CDATA[Low Cost Ultrasonic Flow Meter]]></category>
		<category><![CDATA[Product]]></category>
		<category><![CDATA[Ultrasonic Heat Meter]]></category>
		<category><![CDATA[clamp on flow meter]]></category>
		<category><![CDATA[low cost flow meter]]></category>
		<category><![CDATA[ultrasonic flow meter]]></category>

		<guid isPermaLink="false">http://www.heremeter.com/low-cost-clamp-on-ultrasonic-flowheat-meters.html</guid>
		<description><![CDATA[Low Cost Clamp-on Ultrasonic Flow/heat meters Din rail mounted fixed type ultrasonic flow meter/energy meter Advanced transit-time technology for accurate flow/energy measurement &#160; &#160; Features: 1) Very low cost and an ideal clamp-on ultrasonic flow meters for large quantity application 2)High accuracy,better than ± 1% 3)No-intrusive,no pipe disturbance,no risk of leakage,no moving parts,no pressure drop,low [...]]]></description>
			<content:encoded><![CDATA[<p><span style="font-size: medium;"><span style="color: #0000ff;"><strong><a href="http://www.heremeter.com/wp-content/uploads/2011/08/1271874155_151.jpg"><img style="display: inline; border-width: 0px;" title="1271874155_15" src="http://www.heremeter.com/wp-content/uploads/2011/08/1271874155_15_thumb1.jpg" alt="1271874155_15" width="362" height="232" border="0" /></a> </strong></span></span></p>
<p><span style="font-size: medium;"><span style="color: #0000ff;"><strong>Low Cost </strong><strong>Clamp-on </strong><strong>Ultrasonic Flow/heat meters</strong></span></span></p>
<p><span style="color: #008040;">Din rail mounted fixed type <span class='wp_keywordlink'><a href="http://www.heremeter.com/" title="ultrasonic flow meter">ultrasonic flow meter</a></span>/energy meter</span></p>
<p><span style="color: #008040;">Advanced transit-time technology for accurate flow/energy measurement </span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong><span style="color: #008040;">Features: </span></strong></p>
<p>1) Very low cost and an ideal clamp-on ultrasonic flow meters for large quantity application<br />
2)High accuracy,better than ± 1%<br />
3)No-intrusive,no pipe disturbance,no risk of leakage,no moving parts,no pressure drop,low maintenance<br />
4)Wide pipe size range:1″-240″(DN25mm-DN6000mm)<br />
5)Wide measurement range:0.03-105ft/s(0.01-32m/s)<br />
6)the ultrasonic flow meters is suitable for all common used pipe materials<br />
7)the ultrasonic flow meters is also suitable for most pure liquids and liquids with minor particles<br />
8)Large turn-down ratio<br />
9)Easy clamp-on installing.No pipe cutting and no hole drilling.Save installing cost.<br />
10)Built-in flow totalizers,batch controller and task scheduler<br />
11)Isolated 8-36V DC power supply.<br />
12)LCD backlight 2*20 letters display<br />
13)4 local keys for all parameters setting<br />
14)Versatile inputs/outputs,including 3 way 4-20mA input and 2 way OCT output(relay output) and one way 4-20mA output.<br />
15)Can support both self-powered and loop-powered mode 4-20mA output.  While self-powered used, the power supply must be 24VDC.<br />
16)Isolated RS485 interface with power surge protection. Support MODBUS.Well suited for reliable networking.<br />
17)Optional thermal energy measurement<br />
18)Automatically match transducer to pipe materials and liquid property with proprietary signal quality tracking and self-adaptation technology<br />
19)Low power consumption,less than 0.5W at 9VDC<br />
20) Small size only 90×90×32mm.</p>
<p><strong><span style="color: #008040;">Description:</span></strong></p>
<p>The low cost ultrasonic flowmeter is the latest innovation from Abest Technology. It employs cutting-edge technologies on ultrasonic transit-time measurement, digital signal processing and surface mounting electronics. It provides abundant capabilities for accurate liquid flow measurement from outside of a pipe. The proprietary signal quality tracking and self-adapting techniques allow the system to optimally adapt to different pipe materials automatically.</p>
<p>This unit has four local keys which can be used for setting all parameters,including inputing value.</p>
<p>This type ultrasonic flowmeter can be equipped with an optional key board module. The users can either use the RS-485 interface or the display / keyboard interface to program the flowmeter.<br />
The transducer installation is also simple and no special skills or tools are required.<br />
Due to the non-intrusive nature of the clamp-on technology, there is no pressure drop, no moving parts, no leaks, no risk of contamination, no risk of corrosion, no pressure dependency.<br />
This type ultrasonic flow meter is designed for large quantity, low cost applications. Its unique features, particularly very low cost, very high performance and very small size, make it the ideal choice for industrial automation, processing control, water source management, flow meter networking and OEM applications.<br />
<strong><br />
<span style="color: #008040;">Application:</span></strong></p>
<p>This type ultrasonic  flow meters are designed for large quantity, low cost applications. Benefited from our innovate network interface technique, the ultrasonic flow meter is an ideal choice for industrial automation, processing monitoring, water source management, flow meter networking and OEM applications. It provides reliable measurement in both clean and opaque liquid flow.</p>
<p>&nbsp;</p>
<p><span style="color: #000000;">Examples of applicable liquids are listed as below:<br />
•Water, including hot water, chilled water, city water, sea water, etc.<br />
•Sewage, waste treatment, etc.<br />
•Oil, including crude oil, diesel oil, fuel oil, lubricating oil, etc.<br />
•Chemicals, including alcohol, acids, etc.<br />
•Beverage, food and pharmaceutical processors where non-contact is a must<br />
•HVAC, energy measurement system, etc.<br />
•Solvents </span></p>
<p><strong><span style="color: #008040;">Clamp on ultrasonic flow transducers option</span></strong></p>
<table width="519" border="1" cellspacing="0" cellpadding="2">
<tbody>
<tr>
<td valign="top" width="200"><img style="display: inline; border-width: 0px;" title="s1" src="http://www.heremeter.com/wp-content/uploads/2011/08/s1_thumb1.jpg" alt="s1" width="193" height="82" border="0" /></td>
<td valign="top" width="317">Standard S1 transducers<br />
Pipe size: DN15-DN100mm<br />
Protection class: IP68<br />
Temperature: 0-70C<br />
With magnetic</td>
</tr>
<tr>
<td valign="top" width="200"><a href="http://www.heremeter.com/wp-content/uploads/2011/08/ma1.jpg"><img style="display: inline; border-width: 0px;" title="ma" src="http://www.heremeter.com/wp-content/uploads/2011/08/ma_thumb1.jpg" alt="ma" width="187" height="111" border="0" /></a></td>
<td valign="top" width="317">Standard M1 clamp on transducers<br />
Pipe size: DN50-DN700mm<br />
Protection class: IP68<br />
Temperature: 0-70C<br />
With magnetic</td>
</tr>
<tr>
<td valign="top" width="200"><a href="http://www.heremeter.com/wp-content/uploads/2011/08/L11.jpg"><br />
<img style="display: inline; border-width: 0px;" title="L1" src="http://www.heremeter.com/wp-content/uploads/2011/08/L1_thumb1.jpg" alt="L1" width="201" height="97" border="0" /></a></td>
<td valign="top" width="317">Standard L1 clamp ontransducers<br />
Pipe size: DN300-DN6000mm<br />
Protection class: IP68<br />
Temperature: 0-70C</td>
</tr>
<tr>
<td valign="top" width="200">            <img style="display: inline; border-width: 0px;" title="SH1" src="http://www.heremeter.com/wp-content/uploads/2011/08/SH1_thumb1.jpg" alt="SH1" width="104" height="103" border="0" /></td>
<td valign="top" width="317">High temperature S1 clamp-on transducers<br />
Pipe size: DN15-DN100mm<br />
Protection class: IP68<br />
Temperature: 0-150C<br />
Without magnetic</td>
</tr>
<tr>
<td valign="top" width="200"><a href="http://www.heremeter.com/wp-content/uploads/2011/08/MH11.jpg"><img style="display: inline; border-width: 0px;" title="MH1" src="http://www.heremeter.com/wp-content/uploads/2011/08/MH1_thumb1.jpg" alt="MH1" width="147" height="146" border="0" /></a></td>
<td valign="top" width="317">High temperature  M1 clamp on transducers<br />
Pipe size: DN50-DN700mm<br />
Protection class: IP68<br />
Temperature: 0-150C<br />
Without magnetic</td>
</tr>
</tbody>
</table>
<p><strong><span style="color: #008040;">Insertion and spool piece inline ultrasonic flow transducers option</span></strong></p>
<table width="517" border="1" cellspacing="0" cellpadding="2">
<tbody>
<tr>
<td valign="top" width="258"><a href="http://www.heremeter.com/wp-content/uploads/2011/08/1271875932_521.jpg"><img style="display: inline; border-width: 0px;" title="1271875932_52" src="http://www.heremeter.com/wp-content/uploads/2011/08/1271875932_52_thumb1.jpg" alt="1271875932_52" width="207" height="144" border="0" /></a></td>
<td valign="top" width="257"><a href="http://www.heremeter.com/wp-content/uploads/2011/08/1271875967_831.jpg"><img style="display: inline; border-width: 0px;" title="1271875967_83" src="http://www.heremeter.com/wp-content/uploads/2011/08/1271875967_83_thumb1.jpg" alt="1271875967_83" width="240" height="118" border="0" /></a></td>
</tr>
<tr>
<td valign="top" width="258">Standard insertion  flow  transducers</p>
<p>Pipe size: DN80-DN6000mm</p>
<p>Protection class: IP68</p>
<p>Temperature: 0-150C</td>
<td valign="top" width="257">Long insertion  flow  transducers</p>
<p>Pipe size: DN80-DN6000mm</p>
<p>Protection class: IP68</p>
<p>Temperature: 0-150C</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table width="457" border="1" cellspacing="0" cellpadding="2">
<tbody>
<tr>
<td valign="top" width="253">&nbsp;</p>
<p>&nbsp;</p>
<p><img style="display: inline; border-width: 0px;" title="1271876164_31" src="http://www.heremeter.com/wp-content/uploads/2011/08/1271876164_31_thumb1.jpg" alt="1271876164_31" width="240" height="88" border="0" /></td>
<td valign="top" width="202">             <a href="http://www.heremeter.com/wp-content/uploads/2011/08/1271876177_211.jpg"> <img style="display: inline; border-width: 0px;" title="1271876177_21" src="http://www.heremeter.com/wp-content/uploads/2011/08/1271876177_21_thumb1.jpg" alt="1271876177_21" width="229" height="182" border="0" /></a></td>
</tr>
<tr>
<td valign="top" width="253">PI type ultrasonic flow transducers<br />
Size: DN15,DN20,DN25,DN32,DN40mm<br />
Protection class: IP68<br />
Temperature: 0-150C</td>
<td valign="top" width="202">Inline full bore tube style ultrasonic flow transducers Size:DN50,DN65,DN80-DN1000mm<br />
Protection class: IP68<br />
Temperature: 0-150C</td>
</tr>
</tbody>
</table>
<p><strong><span style="color: #0000ff;">Note: The blue and white color are avaiable now,please check with us before order if have special request.</span></strong></p>
]]></content:encoded>
			<wfw:commentRss>http://www.heremeter.com/product-id-38.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Insertion Ultrasonic Flow meter</title>
		<link>http://www.heremeter.com/product-id-12.html</link>
		<comments>http://www.heremeter.com/product-id-12.html#comments</comments>
		<pubDate>Tue, 06 Sep 2011 02:37:30 +0000</pubDate>
		<dc:creator>heremeter</dc:creator>
				<category><![CDATA[Fixed Ultrasonic Flow Meter]]></category>
		<category><![CDATA[Product]]></category>
		<category><![CDATA[Insertion flow meter]]></category>
		<category><![CDATA[ultrasonic flow meter]]></category>

		<guid isPermaLink="false">http://www.heremeter.com/insertion-ultrasonic-flow-meter.html</guid>
		<description><![CDATA[Insertion (Hot-tap) Ultrasonic Flow meter State-of-the-art Transit-time Ultrasonic Technology Lower cost, good performance &#160; Built-in 4M data logger,more stable and reliable, data logger software for PC available MODBUS Protocol and HART Protocol and Meter-bus Protocol 2-way 3-wire PT100 resistor for thermal energy measurement, higher accuracy and lower cost. &#160; Features: (1).Very good long-term stability and [...]]]></description>
			<content:encoded><![CDATA[<p><strong><span style="color: #0000ff; font-size: medium;"><a href="http://www.heremeter.com/wp-content/uploads/2011/08/mark_1211605782.gif"><img style="display: inline; border: 0px;" title="mark_1211605782" src="http://www.heremeter.com/wp-content/uploads/2011/08/mark_1211605782_thumb.gif" alt="mark_1211605782" width="240" height="220" border="0" /></a> </span></strong></p>
<p><strong><span style="color: #0000ff; font-size: medium;">Insertion (Hot-tap) Ultrasonic Flow meter</span></strong></p>
<p><span style="color: #008040;">State-of-the-art Transit-time Ultrasonic Technology</span></p>
<p><span style="color: #008040;">Lower cost, good performance</span></p>
<p>&nbsp;</p>
<p>Built-in 4M data logger,more stable and reliable, data logger software for PC available</p>
<p>MODBUS Protocol and HART Protocol and Meter-bus Protocol</p>
<p>2-way 3-wire PT100 resistor for thermal energy measurement, higher accuracy and lower cost.</p>
<p>&nbsp;</p>
<p><strong><span style="color: #008040;">Features:<br />
</span></strong>(1).Very good long-term stability and reliability<br />
(2).Pipe size range:DN80-DN6000mm<br />
(3).Wide flow range 0.03 to 105ft/s<br />
(4).Suitable for all commonly used pipe materials<br />
(5).High accuracy (better than ±1%, and could reach to ±0.5% with calibration)<br />
(6).High quality signal. Robust performance<br />
(7).Flexible installation. Easy to remove transducer<br />
(8).GPRS / GSM networking capability with certain model<br />
(9).For pipe size 3&#8243; (DN80) or larger<br />
(10).Ideal for both clean and opaque liquid flow measurements<br />
(11)Temperature range:0-150C<br />
(12)If pipe material can&#8217;t be welded directly, it will special fixing strap.<br />
<span style="color: #0000ff;">    The welding base material of insertion transducers is stainless steel and carbon steel for choice.Please indicate while order.<br />
</span></p>
<p><strong><span style="color: #008040;">Descriptions:<br />
</span></strong>Insertion liquid <span class='wp_keywordlink'><a href="http://www.heremeter.com/" title="ultrasonic flow meter">ultrasonic flow meter</a></span> employs a pair of insertion-type ultrasonic transducers to measure the flow by inserting the transducers into the pipe wall. The transducers do not extrude into the flow, thus, do not generate any disturbance or pressure drop to the flow. Comparing with a clamp-on flowmeter, the biggest advantages of our wetted-type flowmeter are its long-term stability, better signal quality and less installation uncertainty. The last two features can also be translated into higher accuracy.<br />
The insertion liquid flow meter is designed for pipe larger than 3” (DN80mm). For smaller pipe, our spool-piece model, flow cell  inlie flow meter, might be a better choice. When pipe size becomes smaller, the cost of a spool-piece inline transducer comes down.<br />
The Insertion type ultrasonic flow meter is ideal for flow surveys and closed-pipe applications, such as normal water flow measurement (hot/chill water, city water, sea water), sewage and sludge measurement, and measurements of oil (crude/diesel/fuel), chemicals (alcohol, acids, etc.), beverage, and many other liquids.</p>
<p><span style="color: #008040;"><strong>Specifications:<br />
</strong></span>For the insertion transducers, it mainly includes two parts,one is main converter,which we recommend wall mounted unit or low cost unit, and the insertion transducers mainly includes standard insertion type and cement insertion type.</p>
<p>Optional transducers:(For pipe size&gt;80mm)<br />
For samller pipe below DN40mm, we recommend to choose spool piece or flow cell type ultrasonic flow meter.</p>
<table width="532" border="1" cellspacing="0" cellpadding="2">
<tbody>
<tr>
<td valign="top" width="272"><a href="http://www.heremeter.com/wp-content/uploads/2011/08/1245118390_31.jpg"><img style="display: inline; border: 0px;" title="1245118390_31" src="http://www.heremeter.com/wp-content/uploads/2011/08/1245118390_31_thumb.jpg" alt="1245118390_31" width="240" height="181" border="0" /></a></td>
<td valign="top" width="258"><a href="http://www.heremeter.com/wp-content/uploads/2011/08/1245118409_61.jpg"><img style="display: inline; border: 0px;" title="" src="http://www.heremeter.com/wp-content/uploads/2011/08/1245118409_61_thumb.jpg" alt="" width="240" height="157" border="0" /></a></td>
</tr>
<tr>
<td valign="top" width="272">Vertical type insertion transducer</p>
<p>For pipe size 3&#8243; (DN80) or larger</p>
<p>Medium temp.:-40C -160C</p>
<p>Installing space&gt;550mm</td>
<td valign="top" width="258">Insertion type for cement pipes</p>
<p>For pipe size 3&#8243; (DN80) or larger</p>
<p>Medium temp.:-40C -160C</p>
<p>Installing space&gt;700mm</td>
</tr>
</tbody>
</table>
<p>We are developing new version wall mounted unit and will add some good funtion to it which may be a good help for internation selling.</p>
<p>1.Built-in 4M data logger can store over 200,000 lines of data.</p>
<p>Interval time can be set from 1s to 24 hour.</p>
<p>Up to 22 options can be selected for data logging.</p>
<p>2.HART(4-20mA) is optional</p>
<p>Lanaguage version developing news<br />
The wall mounted unit of ultrasonic flow meter has ENGLISH,ITALIAN and CHINESE version for choice.</p>
<p>We will release FRENCH version in the near future.</p>
<p>Meanwhile, we are preparing the GERMAN version information and will try to release GERMAN version ASAP.</p>
<p>Please kindly visit our website for the latest news as we will update once they are available.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.heremeter.com/product-id-12.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Wall Mounted Ultrasonic Flow Meter</title>
		<link>http://www.heremeter.com/product-id-5.html</link>
		<comments>http://www.heremeter.com/product-id-5.html#comments</comments>
		<pubDate>Mon, 05 Sep 2011 14:32:29 +0000</pubDate>
		<dc:creator>heremeter</dc:creator>
				<category><![CDATA[Fixed Ultrasonic Flow Meter]]></category>
		<category><![CDATA[Product]]></category>
		<category><![CDATA[clamp on flow meter]]></category>
		<category><![CDATA[ultrasonic flow meter]]></category>

		<guid isPermaLink="false">http://www.heremeter.com/wall-mounted-ultrasonic-flow-meter.html</guid>
		<description><![CDATA[                                                                                                               [...]]]></description>
			<content:encoded><![CDATA[<p><a href="http://www.heremeter.com/wp-content/uploads/2011/08/wall-mounted-with-M1.jpg">                                                  <img class="size-full wp-image-232 aligncenter" title="wall mounted with M1" src="http://www.heremeter.com/wp-content/uploads/2011/08/wall-mounted-with-M1.jpg" alt="clamp on flow meter" width="261" height="235" /></a></p>
<p><strong><span style="color: #0000ff;">                                                                                         Wall Mounted Ultrasonic Flow Meter</span></strong></p>
<p><span style="color: #008040;">                                                                 &#8211; Clamp-on Transit-time technology,low cost, good performance</span></p>
<p>&nbsp;</p>
<p><span style="color: #0000ff;">Wall-mounted ultrasonic  flow meter is CE approved.</span></p>
<p><span style="color: #0000ff;">A 2G SD data logger for the ultrasonic  flow meter is also available now, for more details,please contact us.</span></p>
<p>In the near future,new function of the <span class='wp_keywordlink'><a href="http://www.heremeter.com/" title="ultrasonic flow meter">ultrasonic flow meter</a></span> will be added as below:</p>
<p>1)Built-in 4M data logger for recording 22 items,more stable and reliable, data logger software for PC available.</p>
<p>2)HART protocol optional</p>
<p>3)Langauge: English,Italian,Chinese now, and Spain,Frech,German,Japanese will be released in the future.</p>
<p><strong><span style="color: #008040;">Descriptions:<br />
</span></strong>The wall mounted ultrasonic flow meter belongs to range of fixed type ultrasonic flow meters, as a good selling product,it has been carefully designed,so it provides abundant capabilities for accurate liquid flow measurement.</p>
<p>The wall mounted unit can support clamp on transducers,insertion hot-tap transducers and inline type transducers.It can be powered by AC and DC power and solar powered.</p>
<p>With clamp-on transducers,it is called as clamp on ultrasonic flow meters and can provide many good features:no need to cut pipe,no direct touch to liquid, no pressure drop, no moving parts, no risk of contamination, no risk of corrosion,and etc.</p>
<p>With insertion transducers, it will be insertion ultrasonic flow meters and can be used for pipe size&gt;DN80 mm.Insertion flowmeter can support higher accuracy flow measurement.With out patented hot-tap installing tool, insertion transducers can be installed without any flow stop.</p>
<p><span style="color: #008080;"><strong>Features:<br />
</strong></span>(1).Guaranteed lowest price on the market.<br />
(2).High accuracy. Normally, ±1% When on-site calibration available, ±0.5%.<br />
(3).Wide flow range 0.03 to 105ft/s.<br />
(4).Wide pipe size range (from 1&#8243; to 240&#8243;). PI type transducer can be made to measure the  min inner diameter of 2mm.<br />
(5).Noninvasive. No pipe disturbance. No moving parts, no pressure drop.<br />
(6).Easy and economical installation. No cutting pipe, non drilling hole.<br />
(7).Suitable for all commonly used pipe materials<br />
(8).Easy to use and set up. Self-explanatory menu programming<br />
(9).Velocity, volumetric and totalized flow<br />
(10).GPRS / GSM networking capability with certain model<br />
(11).Ideal for both clean and opaque liquid flow measurements</p>
<p><span style="color: #008080;"><strong><em>Specifications:</em><br />
</strong></span><span style="color: #0000ff;">Main Unit specifications</span></p>
<table width="515" border="1" cellspacing="0" cellpadding="2">
<tbody>
<tr>
<td valign="top" width="150">Accuracy</td>
<td valign="top" width="363">Better than  ±1% of reading value</td>
</tr>
<tr>
<td valign="top" width="154">Repeatability</td>
<td valign="top" width="360">±0.2%</td>
</tr>
<tr>
<td valign="top" width="157">Velocity</td>
<td valign="top" width="358">±0.03 &#8211; ±105 ft/s (±0.01 &#8211; 32 m/s), bi-directional.</td>
</tr>
<tr>
<td valign="top" width="159">Response Time</td>
<td valign="top" width="357">0.5s (Collecting 128 groups of data each cycle)</td>
</tr>
<tr>
<td valign="top" width="160">Display</td>
<td valign="top" width="356">LCD with backlight.  2&#215;20 letters.   Display instantaneous flow rate, accumulated flow rate (positive, negative and net rates), velocity, time, analog inputs, etc.</td>
</tr>
<tr>
<td valign="top" width="161">Units</td>
<td valign="top" width="355">English (U.S.) or metric</td>
</tr>
<tr>
<td valign="top" width="162">Signal Outputs</td>
<td valign="top" width="354">1).Current output: 4-20mA or 0-20mA. Impedance 600ohm(float blank), Accuracy 0.1%. Module optional.<br />
2).OCT output:  frequency signal for instantaneous flow rate (0-9,999Hz selectable), Module optional.<br />
3.Relay pulse output: pulse signal for accumulated flow rate (positive, negative and net rates);double channel OCT output (pules width of one channel is 6-1000mS,programmable, the fault value is 200ms.<br />
4.Sound alarm:double channel OCT output, 20 type of source signal available<br />
5.digital port: Isolated RS485 SATA</td>
</tr>
<tr>
<td valign="top" width="163">Signal Inputs</td>
<td valign="top" width="354">1) 3 channel 4-20mA inputs (for signals such as temperature, pressure, liquid level, etc.,also as a digital port.)<br />
2)2 channel 3-wire PT100 input can measure heater.</td>
</tr>
<tr>
<td valign="top" width="163">Recording</td>
<td valign="top" width="354">Automatically record the following information:<br />
1) The totalizer data of the last 64 days / 64 months / 64 years;<br />
2) The power time and corresponding flow rate of the last 64 times power on and off events;<br />
3) Allow manual or automatic flow loss compensation;<br />
4) The instrument working status of the last 64 days.<br />
5) Programmable ration controller(control by external input signals or MODBUS command.)<br />
6)One bi-directional SATA port can connect a few external equipment,such as 4-20mA, data logger, printer,etc.<br />
7)Working parameters can be solidified to flash memory, automatically call-out the stored parameters.<br />
8)software updating by email<br />
9)Error self-check,and timer for error time</td>
</tr>
<tr>
<td valign="top" width="163">Communication Interface</td>
<td valign="top" width="354">Isolated RS485 power surge protection, support MODBUS,MODBUS-ASCII is recommended. M-BUS</td>
</tr>
<tr>
<td valign="top" width="163">Enclosure</td>
<td valign="top" width="354">Protection Class:  IP65 (NEMA 4X) Explosive Proof Class: ExdIIBT4 (for model Abtds-100F2V only)</td>
</tr>
<tr>
<td valign="top" width="163">Transducer Cable</td>
<td valign="top" width="354">Shielded transducer cable. Standard length 15ft (5m). Can be extended to 1640ft (500m). Contact the manufacturer for longer cable requirement.<br />
Cable should not be laid in parallel with high-voltage power lines, neither should it be close to strong interference source such as power transformers</td>
</tr>
</tbody>
</table>
<p><span style="color: #0000ff;">Liquid Specifications</span></p>
<table width="524" border="1" cellspacing="0" cellpadding="2">
<tbody>
<tr>
<td valign="top" width="153">Liquid Types</td>
<td valign="top" width="369">Virtually all commonly used liquids (full pipe)</td>
</tr>
<tr>
<td valign="top" width="156">Liquid Temp</td>
<td valign="top" width="366">0˚C &#8211; 150˚C</td>
</tr>
<tr>
<td valign="top" width="159">Suspension concentration</td>
<td valign="top" width="364">&lt; 20,000ppm and small air bubble concentration</td>
</tr>
</tbody>
</table>
<p><span style="color: #0000ff;">Pipe Specifications</span></p>
<table width="527" border="1" cellspacing="0" cellpadding="2">
<tbody>
<tr>
<td valign="top" width="148">Pipe Size</td>
<td valign="top" width="377">1&#8243; &#8211; 240&#8243;(25mm-6000mm)</td>
</tr>
<tr>
<td valign="top" width="150">Pipe Material</td>
<td valign="top" width="375">All metals, most plastics, fiber glass, etc.  Allow pipe liner.</td>
</tr>
<tr>
<td valign="top" width="152">Pipe Straight Section Length</td>
<td valign="top" width="374">Better longer than 15D, where D is pipe diameter. If a pump is near, the straight pipe section following the pumps should be &gt; 30D.</td>
</tr>
</tbody>
</table>
<p><span style="color: #0000ff;">Others</span></p>
<table width="531" border="0" cellspacing="0" cellpadding="2">
<tbody>
<tr>
<td valign="top" width="151">Main unit temp.</td>
<td valign="top" width="378">0˚F &#8211; 176˚F (-10˚C &#8211; 70˚C)</td>
</tr>
<tr>
<td valign="top" width="151">Humidity</td>
<td valign="top" width="378">Main unit: 85% RH. Transducer: water-immersible, water depth less than 10’ (3m)</td>
</tr>
<tr>
<td valign="top" width="151">Power</td>
<td valign="top" width="378">AC: 85-264V/ DC24V</td>
</tr>
<tr>
<td valign="top" width="151">Weight</td>
<td valign="top" width="378">5lb (2.5kg)</td>
</tr>
</tbody>
</table>
<p>Clamp on Ultrasonic FLow Transducers Optional</p>
<table width="530" border="1" cellspacing="0" cellpadding="2">
<tbody>
<tr>
<td valign="top" width="161">Standard  Clamp-on S1 for small size pipes</td>
<td valign="top" width="367">Magnetic with clamp-on fixture<br />
Temp.: 0˚C- 70˚C<br />
Protection class: IP68<br />
For pipe size: DN15-DN100mm</td>
</tr>
<tr>
<td valign="top" width="164">Standard  Clamp-on Type M1 for medium size pipes</td>
<td valign="top" width="365">(magnetic with clamp-on fixture)<br />
Temp.: 0˚C- 70˚C<br />
Protection class: IP68<br />
For pipe size: DN50-DN700mm</td>
</tr>
<tr>
<td valign="top" width="166">Stardard  Clamp-on  L1 for large size pipes</td>
<td valign="top" width="363">Temp.: 0˚C- 70˚C<br />
Protection class: IP68<br />
For pipe size: DN300-DN6000mm</td>
</tr>
<tr>
<td valign="top" width="168">High temperature small transducer&#8212;-standard S1H</td>
<td valign="top" width="362">Temp.: 0˚C- 155˚C<br />
Protection class: IP68<br />
For pipe size: DN15-DN100mm</td>
</tr>
<tr>
<td valign="top" width="169">High temperature medium transducer&#8212;standard M1H</td>
<td valign="top" width="361">Temp.: 0˚C- 155˚C<br />
Protection class: IP68<br />
or pipe size: DN50-DN700mm</td>
</tr>
</tbody>
</table>
<p>Language version developing news</p>
<p>The main unit of ultrasonic flow meter has ENGLISH/ITALIAN and CHINESE/ENGLISH version for choice.  We will release FRENCH and Spain version in the near future. Meanwhile, we are preparing the GERMAN version information and will release GERMAN version ASAP.</p>
<p>Please visit our website times and times for the latest news.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.heremeter.com/product-id-5.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Handheld Ultrasonic Flow Meter</title>
		<link>http://www.heremeter.com/product-id-6.html</link>
		<comments>http://www.heremeter.com/product-id-6.html#comments</comments>
		<pubDate>Sun, 04 Sep 2011 09:46:00 +0000</pubDate>
		<dc:creator>heremeter</dc:creator>
				<category><![CDATA[Handheld Ultrasonic Flowmeter]]></category>
		<category><![CDATA[Product]]></category>
		<category><![CDATA[clamp on flow meter]]></category>
		<category><![CDATA[portable flow meter]]></category>
		<category><![CDATA[ultrasonic flow meter]]></category>

		<guid isPermaLink="false">http://www.heremeter.com/handheld-ultrasonic-flow-meter.html</guid>
		<description><![CDATA[                              &#160;          Handheld Portable Clamp on Transit-time Ultrasonic Flowmeter            Clamp-on Portable Flowmeter,Low cost, good performance &#160; English version data logger software is available. The data is stored on built-in data logger of handheld portable main unit, and the software can download the data to PC and [...]]]></description>
			<content:encoded><![CDATA[<p><strong><span style="color: #0000ff;"> </span></strong></p>
<p><strong><span style="color: #0000ff;">                            <a href="http://www.heremeter.com/wp-content/uploads/2011/08/mark_1271356363.jpg"><img style="display: inline; border-width: 0px;" title="mark_1271356363" src="http://www.heremeter.com/wp-content/uploads/2011/08/mark_1271356363_thumb.jpg" alt="mark_1271356363" width="221" height="240" border="0" /></a></span></strong><strong></strong></p>
<p>&nbsp;</p>
<p><strong><span style="color: #0000ff;">         Handheld Portable Clamp on Transit-time Ultrasonic Flowmeter</span></strong></p>
<p><span style="color: #008080; font-size: x-small;">           <span style="color: #008040;">Clamp-on Portable Flowmeter,Low cost, good performance</span></span></p>
<p>&nbsp;</p>
<p>English version data logger software is available. The data is stored on built-in data logger of handheld portable main unit, and the software can download the data to PC and then exports them as Excel spreadsheet formation.</p>
<p>Now the language version mainly include Chinese,English,French,Spain,Italian,Portuguese,etc. If need special langauge,please indicate it while order,otherwise the goods will be sent at random.</p>
<p><span style="color: #008000;"><strong>Features:<br />
</strong></span>(1).High accuracy. ±1%<br />
(2).Wide pipe size range (3/4&#8243;~240&#8243;)<br />
(3).Suitable for all commonly used pipe materials<br />
(4).Wide flow range (0.03~105ft/s), bi-directional<br />
(5).Easy and low-cost installation. No need for hole drilling, pipe cutting, etc.<br />
(6).Non-intrusive. No pressure drop, no pipe disturbance<br />
(7).Low maintenance<br />
(8).Signal quality tracking and self-adaptation to match pipe and fluid variations<br />
(9).Rechargeable battery for 10 hours of operation.<br />
(10). Built-in data logger<br />
(11).Self-explanatory user interface. Easy to operate<br />
(12).Can be deployed as a remote RTU as well<br />
(13).Light weight (main unit 1.2lbs). Real handheld type.<br />
(14).Ideal for clean and opaque liquid flow</p>
<p><strong><span style="color: #008000;">Description:<br />
</span></strong>Handheld portable <span class='wp_keywordlink'><a href="http://www.heremeter.com/" title="ultrasonic flow meter">ultrasonic flow meter</a></span> provides abundant capabilities for accurate liquid flow measurement. The utilization of proprietary ultrasound transmission / receiving, transit-time measurement and ultrasonic signal processing technologies allows our flow meter to measure liquid flow rate from outside of a pipe reliably and accurately.<br />
The handheld portable clamp-on flow meter is carefully designed so that its user-interfaces are self-explanatory and the instrument is very easy to operate. The unique clamp-on fixture design makes the installation very simple and no special skills or tools required. Due to the non-intrusive nature of the clamp-on technique, there is no pressure drop, no moving parts, no leaks, no risk of contamination, no risk of corrosion, not pressure dependent, and etc.<br />
The handheld portable flow meter is ideal for general flow survey, HVAC hydronic balancing / testing, energy consumption supervision, water conservation management, beverage and food processing, chemical process monitoring, power plant monitoring, and other closed-pipe applications where non-intrusive measurement is required. Benefited from our advanced digital signal processing technology, the handheld ultrasonic flow meter works reliably in both clean and opaque liquid flow. Examples of liquids include but not limited to variety of water (hot/chilled water, city water, sea water), sewage and drain water, oil (crude / diesel / fuel), chemicals (alcohol, acides, etc.),  beverage, food, water/glycol solutions, and other liquids.</p>
<p><span style="color: #008000;"><strong>Specifications:</strong></span></p>
<table width="541" border="0" cellspacing="0" cellpadding="2">
<tbody>
<tr>
<td valign="top" width="157">Linearity</td>
<td valign="top" width="382">better than 0.5%</td>
</tr>
<tr>
<td valign="top" width="157">Accuracy</td>
<td valign="top" width="382">±1%</td>
</tr>
<tr>
<td valign="top" width="157">Response Time</td>
<td valign="top" width="382">0-999 seconds, user-configurable</td>
</tr>
<tr>
<td valign="top" width="157">Velocity</td>
<td valign="top" width="382">±0.03 &#8211; ±52 ft/s (±0.01 &#8211; ±16 m/s), bi-directional</td>
</tr>
<tr>
<td valign="top" width="157">Pipe Size</td>
<td valign="top" width="382">3/4&#8243; &#8211; 240&#8243; (DN20mm &#8211; DN6,000mm)</td>
</tr>
<tr>
<td valign="top" width="157">Pipe Material</td>
<td valign="top" width="382">All metals, most plastics,  lined pipe</td>
</tr>
<tr>
<td valign="top" width="157">Totalizer</td>
<td valign="top" width="382">Three 7-digit totals for net, positive and negative flow respectively</td>
</tr>
<tr>
<td valign="top" width="157">Liquid Types</td>
<td valign="top" width="382">Virtually all clean liquids and liquids with minor solids(&lt;10,000ppm). Full pipe</td>
</tr>
<tr>
<td valign="top" width="157">Units</td>
<td valign="top" width="382">English (U.S.) or other international metric units</td>
</tr>
<tr>
<td valign="top" width="157">Liquid Temp</td>
<td valign="top" width="382">32˚F &#8211; 212˚F (0˚C &#8211; 100˚C) or 32˚F &#8211; 312˚F (0˚C &#8211; 150˚C),depending on different transducer type.</td>
</tr>
<tr>
<td valign="top" width="157">Display</td>
<td valign="top" width="382">LCD with backlight,4&#215;16 letters</td>
</tr>
<tr>
<td valign="top" width="157">Security</td>
<td valign="top" width="382">Setup values Modification Lockout. Access code needs unlocking</td>
</tr>
<tr>
<td valign="top" width="157">Output port and interface</td>
<td valign="top" width="382">9-hole RS232C port with simple flowmeter protocol for PC connecting; One isolated OCT for frequency output and pulse output</td>
</tr>
<tr>
<td valign="top" width="157">Transducer Cable</td>
<td valign="top" width="382">Standard 2&#215;15&#8242; (2x5m).Longer is available upon request.</td>
</tr>
<tr>
<td valign="top" width="157">Transducers</td>
<td valign="top" width="382">Different type transducers optional.</td>
</tr>
<tr>
<td valign="top" width="157">Power Supply</td>
<td valign="top" width="382">3 AAA Ni-H built-in batteries. When fully recharged it will last over 10 hours of operation. 100V-240VAC for the charger</td>
</tr>
<tr>
<td valign="top" width="157">Data Logger</td>
<td valign="top" width="382">Built-in data logger can store over 2000 lines of data</td>
</tr>
<tr>
<td valign="top" width="157">Housing Material</td>
<td valign="top" width="382">Aluminum alloy protective case. Suitable for normal and harsh environment</td>
</tr>
<tr>
<td valign="top" width="157">Case Size</td>
<td valign="top" width="382">7.9&#8243;x3.6&#8243;x1.3&#8243; (200mmx92mmx32mm)</td>
</tr>
<tr>
<td valign="top" width="157">Main Unit Weight</td>
<td valign="top" width="382">1.2 lbs (538g) with batteries</td>
</tr>
<tr>
<td valign="top" width="157">Language</td>
<td valign="top" width="382">English,French,Spainish,Italian,etc</td>
</tr>
</tbody>
</table>
<p><strong><span style="color: #008040;">Clamp on transducer options:</span></strong></p>
<p><strong>Standard Small Size S1-magentic<br />
</strong>Temperature: 0-70 Deg C.<br />
For pipe size: DN20-DN100mm</p>
<p><strong>Standard Medium Size M1-magentic<br />
</strong>Temperature: 0-70 Deg C.<br />
For pipe size: DN50-DN700mm</p>
<p><strong>Standard Large Size L1</strong></p>
<p>Temperature: 0-70 Deg C.<br />
For pipe size: DN300-DN6000mm</p>
<p><strong>Rack Medium Size HM</strong> (magnetic with mounting rack).<br />
Temperature: 0-70 Deg C.<br />
For pipe size: DN20-DN100mm</p>
<p><strong>Rack Medium Size HM</strong> (magnetic with mounting rack).<br />
Temperature: 0-70 Deg C.<br />
For pipe size: DN50-DN700mm</p>
<p><strong>High Temperature Small Size S1H<br />
</strong>Temperature: 0-160 Deg C.<br />
For pipe size: DN20-DN100mm</p>
<p><strong>High Temperature Medium Size M1H<br />
</strong>Temperature: 0-160 Deg C.<br />
For pipe size: DN50-DN700mm</p>
]]></content:encoded>
			<wfw:commentRss>http://www.heremeter.com/product-id-6.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>SD Data Logger Ultrasonic Flowmeter/Heat Meter</title>
		<link>http://www.heremeter.com/product-id-73.html</link>
		<comments>http://www.heremeter.com/product-id-73.html#comments</comments>
		<pubDate>Sun, 04 Sep 2011 04:37:46 +0000</pubDate>
		<dc:creator>heremeter</dc:creator>
				<category><![CDATA[Product]]></category>
		<category><![CDATA[Ultrasonic Flowmeter Helper]]></category>

		<guid isPermaLink="false">http://www.heremeter.com/?p=132</guid>
		<description><![CDATA[From 512M to 8G available,now the default is 2G. The SD memeroy data logger is specially designed for Abest&#8217;s transit-time series ultrasonic flow meters. Users can order it if have such request. The SD data logger will record data outputed by the internal SerBUS port of ultrasonic flow meters as customers&#8217; setting. Please kindly note [...]]]></description>
			<content:encoded><![CDATA[<p><strong><a href="http://www.heremeter.com/wp-content/uploads/2011/08/mark_1296520943.jpg"><img class="alignnone size-full wp-image-331" title="mark_1296520943" src="http://www.heremeter.com/wp-content/uploads/2011/08/mark_1296520943.jpg" alt="" width="572" height="227" /></a><br />
</strong></p>
<p><strong><span style="color: #339966;">From 512M to 8G available,now the default is 2G.</span></strong></p>
<p>The SD memeroy data logger is specially designed for Abest&#8217;s transit-time series ultrasonic flow meters. Users can order it if have such request. The SD data logger will record data outputed by the internal SerBUS port of ultrasonic flow meters as customers&#8217; setting. Please kindly note if a thermal printer have been already connected to the SerBUS port of ultrasonic flow meters, users need to built a power switch to control the printer. By this controlling, it can avoid printing out all of the data sent to  the SD data logger.</p>
<p>The SD data logger doesn&#8217;t need special external power supply, and it steals 3.3VDC power from the ultrasonic flow meters.</p>
<p>The SD data logger mainly include the following items,</p>
<p>1)A data logger processing unit</p>
<p>2)A SD flash memory card</p>
<p>3)A triple-core connection wire</p>
<p>4) A SD flash memory card reader</p>
<p>The detailed setting for the data logger</p>
<p>Users need to make the following setting so that to make the SD data logger working properly</p>
<p>1) Set what data to be recorded in window menu M50</p>
<p>2)Set start time,interval time and recording times of data logger in winow menu M51. If input start time **.**.** in M51, it means the data will be recored at once. If input recording times of 9999, it will means the ultrasonic flow meters will output data without stop.</p>
<p>3). Set the data recording direction,and should select &#8216;Send Data To Internal SerBus&#8217;,then the data will recored in the SD data logger.</p>
<p>Please kinly note not each type of ABEST&#8217;s ultrasonic flowmeter can be used with the SD data logger, so please kindly check with us if you have such request.</p>
<p>Working process expression</p>
<p>After connecting to the SerBUS port and making the setting above, a file name of PRIN.TXT will be created automatically by the SD data logger process unit. If the name file has been existed in the data logger, the processing unti won&#8217;t overwrite it, and just append the new data entries to the existing file.So the user should delete the existed file of PRINT.TXT by using PC in order to make full use of the storing space of the SD memory.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.heremeter.com/product-id-73.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Introduction principles of water purifying</title>
		<link>http://www.heremeter.com/product-id-88.html</link>
		<comments>http://www.heremeter.com/product-id-88.html#comments</comments>
		<pubDate>Sun, 04 Sep 2011 03:59:34 +0000</pubDate>
		<dc:creator>heremeter</dc:creator>
				<category><![CDATA[Tech Info]]></category>
		<category><![CDATA[Technologies]]></category>

		<guid isPermaLink="false">http://www.heremeter.com/?p=82</guid>
		<description><![CDATA[As the human being development become more and more advanced, the environment pollution has been more and more serious, especially water pollution. In order to ensure the healthy of people and safety of drinking water, the concept of water purifying has been up and a hot topic, thus, also followed by various water purifying technology. [...]]]></description>
			<content:encoded><![CDATA[<p>As the human being development become more and more advanced, the environment pollution has been more and more serious, especially water pollution. In order to ensure the healthy of people and safety of drinking water, the concept of water purifying has been up and a hot topic, thus, also followed by various water purifying technology.</p>
<p>Water purifying means to utilize water purifying technology to get rid of plenty of organic intergradient, heavy metal ion, detrimental impurity and bacteria, and reserve helpful trace elements to human body. After treatment, water will be clean, sweet, full of oxygen and drinking directly.</p>
<p>Purified water: Utilize normal hyperfiltration technology to get rid of organic intergradient, inorganic intergradient, heavy metal ion, detrimental impurity, bacteria, minerals, then make water drunk directly.</p>
<p>Microfiltration: Filtration accuracy is 0.03-15um.It is a film process of mesh structure filtrating propelled by static pressure.</p>
<p>Ultrafiltration: The filtration accuracy lies between microfiltration and nanofiltration, its range is 0.002um-0.1um. It use pressure difference technology to get rid of the detrimental mineral, including iron rusty, silt, bacteria, etc, keep helpful things to human body by make water flow from higher pressure side to lower pressure side. The technology is core part of mineral water producing line.</p>
<p>Nanofiltration: The filtration lies between ultrafiltration and hyperfiltration. It has a feature of high removing ratio of specific solute which is mainly 1 nm grain, even though under very low pressure. The technology is usually used to remove Ca,Mg, peculiar smell, chromaticity, pesticide, synthetic detergent, solubility organics and evaporation residuum. Its major application field is to soften high hardness water and desalt.</p>
<p>Hyberfiltration: Hyberfiltration technology is initially developed for outer space, it is high accuracy film separation technology by pressure difference. Its accuracy is 0.0001um. From theoretically speaking, it can remove all of impurity (including detrimental and helpful) and only keep hydrone. The technology is usually applied in purify water, industry ultrapure water and medicine ultrapure water. By controlling system, pressure need to be added for origin water to wash Hyberfiltration film so as to improve life of the film.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.heremeter.com/product-id-88.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Knowledge about pretreatment of Water</title>
		<link>http://www.heremeter.com/product-id-93.html</link>
		<comments>http://www.heremeter.com/product-id-93.html#comments</comments>
		<pubDate>Sun, 04 Sep 2011 02:08:49 +0000</pubDate>
		<dc:creator>heremeter</dc:creator>
				<category><![CDATA[Tech Info]]></category>
		<category><![CDATA[Technologies]]></category>

		<guid isPermaLink="false">http://www.heremeter.com/?p=53</guid>
		<description><![CDATA[What is the pretreatment of water? Pretreatment of water is fine to deal with in the water before the initial pre- processing, in order to deal with water when the essence of good results, improvement in water quality. Because the nature of water has a large number of impurities, such as silt, clay, organic matter, [...]]]></description>
			<content:encoded><![CDATA[<p>What is the pretreatment of water?</p>
<p>Pretreatment of water is fine to deal with in the water before the initial pre- processing, in order to deal with water when the essence of good results, improvement in water quality. Because the nature of water has a large number of impurities, such as silt, clay, organic matter, microorganisms, such as mechanical impurities. The existence of these impurities seriously affect water quality and refined treatment and must be dealt with in the sperm prior to the reduction or removal of some impurities, which requires pre-treatment, sometimes also known as pre-treatment.</p>
<p>What are the main methods of pre-treatment?</p>
<p>A lot of pre-treatment methods, there are filtration, coagulation, clarification, softening, disinfection, pre-Shen, etc. After pretreatment with these methods, you can water the suspended solids (turbidity), color, colloidal matter, organic matter, iron, manganese, temporary hardness, microorganisms, volatile substances, such as dissolved gas to remove impurities or reduced to a certain degree of extent.</p>
<p>Filtering water will be handled by devices equipped with special filter materials, such as the various filter and so on, retain water impurities, be removed.</p>
<p>Coagulation using ferric, aluminum, polymer, such as coagulant, and the impurities in the water through the flocculation and bridging to form large particles of sediment, and then through other devices such as clarifiers, filter pools, etc., be removed.</p>
<p>Coagulant to clarify the role through the formation of large particles and sediment in the tanks to clarify the separation of sediment removed, water is clarified.</p>
<p>Softening by chemical agents, such as lime water soda powder to remove the water hardness bicarbonate; or using methods such as cation exchange resin to remove water calcium, magnesium, iron ions, this process is known as softening.</p>
<p>Disinfection by adding biocides, such as liquid chlorine, bleaching powder, etc., is used to kill micro-organisms in the water.</p>
<p>Pre-Shen is a large capacity, low flow rate to deal with natural precipitation, such as settling ponds, pre-sedimentation tank.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.heremeter.com/product-id-93.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Ultrasonic Distance Finder</title>
		<link>http://www.heremeter.com/ultrasonic-distance-finder.html</link>
		<comments>http://www.heremeter.com/ultrasonic-distance-finder.html#comments</comments>
		<pubDate>Thu, 01 Sep 2011 08:19:28 +0000</pubDate>
		<dc:creator>heremeter</dc:creator>
				<category><![CDATA[Product]]></category>

		<guid isPermaLink="false">http://www.heremeter.com/ultrasonic-distance-finder.html</guid>
		<description><![CDATA[&#160; Ultrasonic distance meter utilizes ultrasonic time difference technology to measure distance,area and volume.Ultrasonic distance meter has function of laser location pointer,reading unit selection, auto power OFF,and etc.Ultrasonic distance meters are widely used for the measurement of building,house,etc. Technical Features *Store and display data used in area and volume calculation *Calculate sum,area and voluem *Imperial [...]]]></description>
			<content:encoded><![CDATA[<p>&nbsp;</p>
<p>Ultrasonic distance meter utilizes ultrasonic time difference technology to measure distance,area and volume.Ultrasonic distance meter has function of laser location pointer,reading unit selection, auto power OFF,and etc.Ultrasonic distance meters are widely used for the measurement of building,house,etc.</p>
<p><strong><span style="color: #008000;">Technical Features </span></strong></p>
<p>*Store and display data used in area and volume calculation<br />
*Calculate sum,area and voluem<br />
*Imperial and metric units selection<br />
*Auto Power Off for saving energy<br />
*Upto 18m distance measurement<br />
*2-postion distance measurement<br />
*With built-in laser pointer(Depending on different model) helps to easy distance measurement.</p>
<p><strong><span style="color: #008000;">Handheld Ultrasonic Distance Meter Measurement</span></strong></p>
<p><a href="http://www.heremeter.com/wp-content/uploads/2011/09/EM59.jpg"><img style="display: inline; border: 0px;" title="EM59" src="http://www.heremeter.com/wp-content/uploads/2011/09/EM59_thumb.jpg" alt="EM59" width="170" height="240" border="0" /></a></p>
<p>Technical Specification<br />
*Transmit frequency:40KHz<br />
*Accuracy:+/- 0.5%<br />
*Resolution:0.01m<br />
*Working temp. 0-50 Deg.C<br />
*Weight:100g(inc.battery)<br />
*Max range:18m(In static air)<br />
*Power supply:9V 6F22<br />
*Dimension:128×53×36mm</p>
<p><strong><span style="color: #008000;">Ultrasonic Distance Meter Tape Measurement</span></strong></p>
<p><a href="http://www.heremeter.com/wp-content/uploads/2011/09/EM56M.jpg"><img style="display: inline; border: 0px;" title="EM56M" src="http://www.heremeter.com/wp-content/uploads/2011/09/EM56M_thumb.jpg" alt="EM56M" width="183" height="187" border="0" /></a></p>
<p>Technical Specification<br />
*Transmit frequency:40KHz<br />
*Accuracy:+/- 0.5%<br />
*Working temp. 0-50 Deg.C<br />
*Resolution:0.01m<br />
*Weight:100g(inc.battery)<br />
*Max range:18m(In static air)<br />
*Power supply:23A 12V<br />
*Dimension:72×75×33mm</p>
<p><span style="color: #0000ff;">Note: Because of the small size design,there is no space to add laser pointer,so the model has no laser pointer. </span></p>